Sure Bail 470017 Float Switch Wiring Diagram: A Complete Guide

The Sure Bail 470017 float switch is a reliable device commonly used in water level management systems, such as sump pumps, sewage systems, and water tanks.

Proper wiring and installation are essential for its efficient operation. Below is a step-by-step guide to understanding its wiring diagram and setup.


Key Components and Wiring Basics

  1. Components Needed:
    • Sure Bail 470017 float switch
    • Power source (110V or 220V depending on setup)
    • Pump or load device
    • Wire connectors and electrical tape
    • Wire stripper and screwdrivers
  2. Wiring Diagram Overview:
    • Common (COM) Wire: Connects to the power source.
    • Normally Open (NO) Wire: Activates the pump when the float rises.
    • Normally Closed (NC) Wire: Optionally used for reverse operations, such as turning off a device when the float rises.

Step-by-Step Wiring Instructions

  1. Turn Off Power: Ensure the power supply is disconnected to prevent electrical hazards.
  2. Prepare Wires: Use a wire stripper to expose the necessary lengths of wire.
  3. Connect the Wires:
    • Attach the COM wire to the power source.
    • Connect the NO wire to the pump’s power input.
    • Insulate unused wires, such as the NC wire, if not required.
  4. Secure Connections: Use wire connectors and electrical tape to prevent exposed connections.
  5. Mount the Float Switch: Position the float switch inside the tank or reservoir, ensuring it can move freely without obstructions.

Testing and Maintenance

  1. Test the Setup: Reconnect power and observe the float switch operation as the water level changes. The pump should activate and deactivate appropriately.
  2. Regular Maintenance: Inspect the float and connections periodically for wear, debris, or corrosion. Keep the system clean to ensure reliable operation.

Common Troubleshooting Tips

  • If the pump doesn’t activate:
    • Check all wire connections and ensure they are secure.
    • Verify that the float can move freely without obstructions.
  • If cycling occurs too frequently:
    • Ensure the water level and pump settings are correctly aligned.
  • Replace frayed or damaged wires immediately to maintain safety.

The Sure Bail 470017 float switch provides a durable and efficient solution for managing liquid levels in various applications. Proper wiring and installation ensure its longevity and reliability in both residential and commercial settings.